We install fiberglass three ways in Richmond homes: batts and rolls in open walls, floors and attic floors, and blown-in fiberglass in attics. It's still a good choice where the space is open and dry and the insulation is cut to fit. Ask for a free estimate and we'll write down the product, the R-value and the square footage.
Yes, with limits. Fiberglass is made with 40 to 60 percent recycled content, depending on the maker and the plant.
The limit is air. Fiberglass doesn't stop air on its own, and a batt that's gapped or squashed performs worse than its label says. So we seal air leaks first and cut each batt to its cavity.

Batts and rolls fit anywhere the framing is open: wall studs before drywall, floor joists over a crawl space, garage or unheated basement, and open attic floors. That means additions, remodels, gutted rooms, garages and framed basement walls.
Fit is what makes them work. A batt that's too narrow leaves gaps. One that's too thick gets squashed. Both give up R-value. We cut around wiring and boxes so the batt fills the bay edge to edge.
A room over a garage has its own page: see garage and bonus-room insulation.
Batts that sag or lie on the ground have stopped insulating the floor above, and we refit them. If damp is why they came down, that gets fixed first. See crawl space insulation and wet crawl spaces.
On an attic floor, blown-in fiberglass usually does better than batts. It fills around joists, wiring and corners where batts leave gaps, and it settles less than cellulose.
We blow it to the R-value written on your estimate. The full story is on our blown-in insulation page, and attic insulation covers how much your attic needs.
Here is the general guide to what each batt is for:
That's a guide to what fits the framing, not the law. For deeper attic levels we blow the insulation in. What Virginia's energy code asks for is on the R-value page.
Yes, if the old batts are dry, in place and not matted down. We lay the new layer across the joists, and we use unfaced batts (no paper or foil) so moisture isn't trapped between the layers.
To judge old fiberglass, measure its depth in inches and multiply by 3.2. That gives a rough R-value to plan from. Wet, flattened or damaged batts come out first: see insulation removal.
Flash and batt means we spray a thin coat of foam to seal the cavity, then fill the rest with fiberglass batts. The foam stops the air, and the batts add the depth.
It suits open walls in an addition or remodel when you want a tight seal without filling every stud bay with foam. More on foam is on our spray foam insulation page.
Our installed price for R-38 batts on an attic floor is $1.35 to $2 per square foot. That covers batts laid between and across the ceiling joists and cut around obstructions.
The price moves with R-value, faced or unfaced batts, access and clearance, and job size. See attic insulation cost and insulation cost overall for the rest.
Fiberglass fits open, dry cavities and wide attic floors. How it stacks up against spray foam and cellulose is on the types of insulation page.
Both are the same fiberglass. Batts come precut in set lengths, and rolls are one long strip we cut to the space. We choose by the framing and the length of the run, and the estimate names the one we'll use.
Faced batts have a paper or foil facing that works as a vapor retarder, so they go where one is required. Unfaced batts have no facing, so they go over old insulation, where a second facing would trap moisture between the layers.
Not as batts. Closed walls get filled through small holes; see wall insulation.
Tell us what you have: open walls, a cold floor or a thin attic. We'll put the product, R-value and square footage in writing.
Licensed & insured · Free estimates