
Virginia's current code puts the minimum ceiling insulation in Richmond at R-60. That's the number for new work, and the part of your house we alter is held to it. An attic we leave alone doesn't have to be upgraded. We measure your attic for free and put the R-value we'll reach on your written estimate.
R-value measures how well insulation resists heat flow. The higher the number, the less heat gets through your ceiling, walls or floor, in winter and in summer.
Every material has its own R-value per inch. The total comes from the material and how deep it is, so two attics of the same depth can have very different R-values. That's why our estimate names the R-value we reach, not just the inches.
Virginia's State Building Codes Office says the 2021 Virginia Residential Code raised the minimum ceiling insulation in Climate Zones 3 and 4 from R-49 to R-60. Richmond is in zone 4A, so R-60 is the ceiling minimum for new work here.
One statewide code applies. The 2021 edition took effect January 18, 2024. A city or county can't write a stricter insulation code of its own, and your local building department enforces the same code everywhere in Virginia. The 2024 edition is not in force.
ENERGY STAR's guidance for zone 4A is R60 in an attic with no insulation. If you already have 3 to 4 inches, it says to add R49 on top. Under floors it says R19. This is guidance for retrofits, not the code.
On the 2021 climate map the code uses, every county we serve but one is zone 4A, the same as on the older map. Sussex County is the one the 2021 map moved, and the state's ceiling minimum there is R-60 as well. More on that county on our Sussex County page.
Not by today's numbers. R-38 is below the ceiling minimum for new work and short of the R60 ENERGY STAR recommends for a zone 4 attic.
An attic that already has R-38 doesn't have to be torn out for code. If you want to reach the guidance level, we measure first and then add on top. See how that goes on our attic insulation page.
No. When part of an existing home is altered, Virginia's code holds that part to the energy code as it applies to new work. Parts that are not altered don't have to be brought up to today's levels.
If a wall, rafter or floor cavity in the insulated shell is opened up, it must be filled with insulation of at least R-3 per inch, or to the code table value. The code makes an exception where less than 60 square feet of wall or floor cavities are exposed.
This is a general trade guide to batt and blown levels. For walls, Virginia's amended energy code table shows R-15 (or 13+1h) for wood-frame walls in climate zones 3A, 4A and 5A.
Not sure which material gives which R-value? Our comparison of insulation types lines them up.
In the City of Richmond, yes. The city requires a building permit before any alteration to a building, and its list of work that needs no permit doesn't name insulation. The city also calls for an insulation inspection after framing is approved and all insulation is installed. Its plan guide asks for the R-value of any wall, floor or rafter cavity opened up in a renovation, and attic and under-floor insulation is checked at the final inspection.
Work that is normally exempt may need a permit in a locally designated historic district. Our wall insulation page covers that.
The rule differs by place. Chesterfield County lists 'Adding insulation' as needing no permit. Sussex County treats insulation as permit work. Henrico County's no-permit list does not name insulation. Goochland requires a permit to alter any building. Petersburg requires permits for all work except ordinary repairs and does not name insulation. Elsewhere, insulation is not on Virginia's statewide list of exempt work, and your local building official decides whether your job needs a permit. They may exempt minor, ordinary repairs. See the areas we serve for your town.
We pull the permit where one is needed.
We measure your attic for free. We check the depth in several spots, identify what's up there and work out the R-value you have now.
You can ballpark it yourself with ENERGY STAR's rules of thumb: multiply the depth in inches by about 2.5 for loose fiberglass, 3.7 for loose cellulose or 3.2 for fiberglass batts. So 4 inches of loose cellulose is only about R-15. These are rough guides for judging what's already there, not product ratings.
Then we tell you what it takes to reach the level you want. Ask for your free estimate and we'll set a time.
R-30 resists more heat, so it's the better of the two for an attic. Both are well under what the code now asks for new work, so neither is where we'd stop on a bare attic. R-19 earns its place under floors and in deeper wall cavities.
Not by itself. Air leaking through the attic floor, or insulation that is packed down or has gotten wet, cuts what the rated number delivers. A high R-value does its job when the attic is sealed and the insulation is dry and fluffed to its full depth.
Call us or ask for a free estimate. We'll measure your attic and put the R-value we'll reach in writing.
Licensed & insured · Free estimates